ACD/LogD and ACD/LogD Sol Batch
Click image to magnify
|
Now Available for Linux |
|
ACD/LogD Batch and ACD/LogD Sol Batch allow rapid and automatic calculation of accurate octanol-water partition coefficients for thousands of partially dissociated compounds at any pH from 0 to 14. The LogD module also allows rapid prediction of the bioconcentration factor (BCF) and the organic carbon adsorption coefficient (Koc), depending on the options selected.
For more information on the combined pKa/logP algorithm
used to calculate the dissociative octanol-water partition coefficient
- as well as a brief description of its role relative to logP
- please see the ACD/LogD description.
ACD/LogD Batch contains the same capabilities as ACD/LogD Suite, but is stream-lined for power users who require thousands of logD values at a time. In addition to the logD calculation, you may also calculate the pKa and logP values, and related parameters in a batch mode.
ACD/LogD Sol Batch, in addition to the above-mentioned capabilities, also enables batch calculation of solubility in water, including the pH-dependent solubility, intrinsic solubility and solubility in pure water. It also calculates distribution of different ionic forms at different pH. Please review the ACD/Solubility Batch description for more detail.
This package is available for Microsoft Windows, SUN, and Linux platforms, and can be run from a Windows command line.
How ACD/PhysChem Batch: LogD and LogD Sol Modules work:
I. Input file such as:
- ACD/ChemFolder database (.CFD)
- SMILES text file (.TXT)
- MDL SDfile (.SDF)*
- ISIS database (.DB)**
*Note: For more detail about this common text data exchange format, please refer to "MDL File Formats" at the MDL Inc. web site.
**Note: ISIS/Base 2.2 must be installed on the same PC.
II. Set options:
- LogD at any 5 fixed pH values within the 0 to 14 pH range.
-OR-
LogD at any pH in range 0-14 with any step (14>step>0).
- Calculation of logD, bioconcentration factor, and adsorption coefficient.
- Time limit for one structure calculation.
- Choose other parameters to calculate: pKa, logP, PSA, etc.
- Specify algorithms of calculation (choose from two).
- With ion pairs partitioning; the algorithm assumes that any ionic species can be distributed between water and octanol.
- Without ion pair partitioning; the algorithm assumes that only species with a total charge of zero can be distributed between water and octanol (others only in water).
III. Choose to report results to .DB, .SDF, .RDF, .CFD, or .TXT files.
|